Octave band calculator

Centre and edge frequencies for any fraction of an octave, and the band any frequency falls in.

Band width
Band system
Table range

37 bands of 1/3 octave (base 10: octave ratio 10^0.3 ≈ 1.99526). Each band is 25.89 % wider than the one below; its edges sit a factor 1.12202 below and above the centre; bandwidth 23.08 % of the centre.

Nominal centre1 kHz
Exact centre1000.00 Hz
Band edges891.25 – 1122.02 Hz
Bandwidth230.77 Hz

1000.00 Hz is in the 1/3 octave band with the nominal centre 1 kHz (exact 1000.00 Hz, from 891.25 to 1122.02 Hz), 50 % of the way up the band.

37 bands
Nominal (Hz)Exact centreLower edgeUpper edgeBandwidth

How to use the octave band calculator

  1. Choose the band width: 1/1 for octaves, 1/3 for third octaves, or a narrower fraction.
  2. Keep Base 10 to match sound level meters, RTAs and noise reports, or pick Base 2.
  3. Type a frequency to see the band it falls in, or click the band strip. The table below lists every band with its exact centre, edges and bandwidth; copy it or save it as CSV.

How to read the table

800 1000 1250 891.25 Hz 1122.02 Hz centre 1000 Hz · bandwidth 230.77 Hz lower edge → ← upper edge (log frequency)
Third-octave bands touch each other: the upper edge of one is the lower edge of the next.

Each row is one band. The exact centre comes from the formula in the standard, and the two edges sit the same ratio below and above it, so on a log scale the centre is right in the middle. In base 10 the third-octave band at 1 kHz runs from 891.25 to 1122.02 Hz; the next band starts exactly where this one stops, so every frequency belongs to one band. A frequency exactly on an edge counts in the upper band.

The nominal centre is the short, rounded label people use: 31.5 Hz for an exact 31.62 Hz, or 63 Hz for 63.10 Hz. For octave and third-octave bands these labels are the standard ones; for 1/6 octave and narrower the tool rounds the exact centre to 3 significant figures. The bandwidth grows with frequency: every third-octave band is about 23 % of its centre wide, so 46 Hz at 200 Hz but 4.6 kHz at 20 kHz.

Octave and third-octave bands always have a band centred on 1 kHz. The even fractions, 1/6, 1/12 and 1/24 octave, are set out so that 1 kHz falls on an edge instead: the 1/6-octave bands either side of it are centred on 944.06 Hz and 1059.25 Hz. That keeps every narrow band inside one third-octave band, so the narrow bands split each wider band evenly. If you type 1000 Hz with 1/6 octave chosen, the tool tells you it sits exactly on an edge.

Use cases

RTA band labels

A real-time analyzer shows 31 bars between 20 Hz and 20 kHz, labelled with nominal centres such as 25, 31.5 and 40 Hz. When a bar jumps, type the frequency you suspect, say a 120 Hz hum harmonic, to see which bar it lands in: here the 125 Hz band, which runs from 112.2 to 141.3 Hz. Our 1/3-octave RTA uses these same base-10 bands.

Noise reports

Building and environmental noise reports often give levels per octave band, commonly 63 Hz to 8 kHz, and acoustic panels list absorption the same way. To compare a reading from another tool with such a table, check that both use the same band edges: the 500 Hz octave band covers 354.8 to 707.9 Hz, so a fan whine at 720 Hz belongs in the 1 kHz octave. Reverb time is quoted per octave band too; see the reverb time per band.

Filter design

When you build a filter bank for an analyzer or an equaliser, the edges in the table are the −3 dB points each band filter should have. A 1/12-octave band is about 5.8 % of its centre wide, which is close to the spacing of semitones, so 1/12-octave analysis lines up roughly with musical notes. Use CSV to paste the edges straight into a spreadsheet or code.

Base-10 vs base-2 bands

There are two ways to define an octave. Base 2 uses a ratio of exactly 2 between band centres, the musical octave. Base 10, used by the ANSI S1.11 and IEC 61260 standards and the default here, uses 10^(3/10), which is 1.99526: almost 2, but ten third-octave bands then make exactly one decade, so the pattern repeats at every power of ten (100, 1000, 10 000 Hz). The difference is small, about 0.24 % per octave, but it adds up far from 1 kHz: the base-10 third-octave band named 20 Hz is centred on 19.95 Hz, the base-2 one on 19.69 Hz. Use base 10 to match sound level meters and published data.

The formulas are short. With G the octave ratio (1.99526 or 2) and b the fraction (3 for third octaves), the centre of band number x is 1000 × G^(x/b) when b is odd, or 1000 × G^((2x+1)/(2b)) when b is even. The edges are the centre divided and multiplied by G^(1/(2b)), which for third octaves is about 1.122. More tools for rooms are in the room acoustics tools.

FAQ

What is a 1/3 octave band?

A band one third of an octave wide; 31 of them cover 20 Hz to 20 kHz.

Why are band centres like 31.5 and 63 Hz?

They are rounded “nominal” values of exact base-10 frequencies from the standard.

How are band edges found?

Lower edge = centre ÷ 2^(1/6), upper edge = centre × 2^(1/6) for 1/3 octave.

Which standard does it use?

ANSI S1.11 / IEC 61260 base-10 by default, with base-2 as an option.

Written and tested by the SpectrumAnalyzer.app team · Last checked

How we tested: Checked against the formulas of IEC 61260-1 by hand: the 1 kHz third-octave band runs from 891.25 to 1122.02 Hz, the 31.5 Hz band is centred on 31.62 Hz, the base-2 octave at 1 kHz runs from 707.11 to 1414.21 Hz, and 31 third-octave bands cover 20 Hz to 20 kHz.