Reverb time (RT60) meter

Clap, pop a balloon or play a noise burst to see how long your room rings, band by band.

Press Arm, then clap once

The browser asks to use your microphone. Your sound stays on this device.

Or drop a recording of a clap here.

RT60 (500 Hz–1 kHz)—
EDT · broadband—
Shots0 of 5
Verdict—

Room type
Shots

    Up to 5 shots are averaged. Move the mic or the clap spot a little between shots.

    Results by band
    Band (Hz)EDT (s)T20 (s)T30 (s)RT60 (s)Range

    RT60 comes from T30 when the decay range is at least 45 dB. * = from T20 (35–45 dB of range). ! = unreliable: less than 35 dB of decay above the noise. ± = spread between shots.

    Fitted line shown
    Line in the decay chart
    EDT: 0 to −10 dB. T20: −5 to −25 dB. T30: −5 to −35 dB.
    Noise burst

    Pink noise plays from this device's speaker (or the speaker it is connected to) and stops sharply; the mic records how the room dies away. Bluetooth delay does not matter.

    Source

    The mic turns off after each shot. Recordings are read on this device only; they are never uploaded.

    Export and share

    CSV holds the average and every shot per band. The link keeps your settings and room size, never your sound.

    Recent results
      Sound never leaves your device. Nothing is uploaded. Space armB noise burst← → band

      How to use the RT60 meter

      1. Put the phone or laptop where you sit or work, at ear height and at least 1 m from any wall. Press Arm and allow the microphone.
      2. Keep quiet for half a second while the tool measures the room noise. When it shows Clap now, clap once, hard and sharp, about 2 m from the mic, or pop a balloon. Then stay still.
      3. The tool records the decay and stops on its own when the room is quiet again. The results appear per octave band, with a verdict for the room type you choose.
      4. Press Arm again and repeat from another spot. Up to 5 shots are averaged, which smooths out the random part of a single clap.

      No clap? Press Noise burst. The tool plays one second of pink noise through your speaker, cuts it off sharply and measures how the room dies away after it. Turn the volume up first, because the burst must be about 40 dB louder than the room. You can also open a recording, such as a phone voice memo with a few claps and two seconds of quiet after each. The tool finds up to 5 claps in the file. To see a result without a mic, choose Demo room.

      How to read RT60 per band

      Fitted line: −60 dB at 0.60 s so RT60 = 0.60 s Level Decay curve (smoothed) Noise floor T30 range: −5 to −35 dB 0−20−40−6000.20.40.60.81.0 sTime after the clap · level in dB
      One band of a room with an RT60 of 0.6 s. The fit uses the straight middle part, well above the noise floor.

      The top chart shows how the sound dies away in one band. The faint blue line is the raw level, the amber line is the smoothed decay (the sound energy added up backwards from the end, called Schroeder integration) and the dashed coral line is the straight line fitted to it. RT60 is the time that line takes to fall 60 dB.

      Few rooms give 60 dB of clean decay above their background noise, so the tool measures a shorter part and scales it up. T20 uses the fall from −5 to −25 dB and T30 the fall from −5 to −35 dB. EDT, the early decay time, uses only the first 10 dB. It is closest to how reverberant a room sounds while people talk or play.

      The lower chart gives RT60 for each octave band from 125 Hz to 8 kHz, with the target range of your room type shaded green. Click a bar to see its decay. Most rooms ring longer in the bass: a living room may read 0.8 s at 125 Hz and 0.4 s at 4 kHz. The headline number is the average of the 500 Hz and 1 kHz bands, the usual single value.

      “Uses T20” and “unreliable”

      A trustworthy fit needs room under the decay. T30 needs at least 45 dB between the start of the decay and the noise floor, and T20 needs 35 dB. With less, the tool uses T20 and marks it with *, or marks the band with ! when even 35 dB is missing.

      Use cases

      Home studio

      A small control room of 3.5 × 4 × 2.5 m should ring for about 0.2 to 0.4 s. Bare, it often reads 0.7 s in the mid bands and over 1 s at 125 Hz, with a fluttery echo after each clap. Panels at the side-wall reflection points and on the ceiling usually bring the mids down to about 0.35 s. The bass needs thick corner traps, and the room mode calculator shows which notes will boom.

      Home theatre

      Clear dialogue needs about 0.3 to 0.5 s. A media room with a tiled floor and a glass wall can read 0.8 s, and voices blur into the music. A thick rug, heavy curtains over the glass and a full bookshelf often bring it near 0.5 s without making the room feel dead.

      Classroom or office

      Speech is easy to follow at 0.4 to 0.7 s; school standards for small classrooms often ask for 0.6 s or less. A hard classroom at 1.2 s makes the teacher strain and children miss words. Acoustic ceiling tiles fix most of it, so measure before and after to show the change.

      Before and after panels

      Take 5 shots before you change anything; the result is kept under Recent results. After the panels go up, measure again and press Compare on the old result: it appears as a dotted line on the band chart. A typical result: the mids fall from 0.62 to 0.41 s, while the 125 Hz band hardly moves, since thin panels do little for bass.

      Tips for accurate results

      Switch off fans, air conditioning and music, and close the windows: every 10 dB of background noise you remove gives 10 dB more decay to measure. A balloon pop has far more energy below 250 Hz than a clap, so use one when the bass bands say “noisy”. Many phones and some laptops keep automatic gain on, which turns the level up as the sound fades and makes decays read short; the tool warns you when the browser reports it. Do not stand between the clap and the mic, and keep the phone on a table or stand rather than in your hand.

      Target reverb times by room type

      These are common ranges for the average of the 500 Hz and 1 kHz bands in furnished rooms of normal size. Bigger rooms of the same type can sit near the top of the range.

      RoomGood RT60Why
      Vocal booth0.1–0.2 sDry voice, no room sound on the recording
      Home studio control room0.2–0.4 sYou hear the speakers, not the room
      Home theatre0.3–0.5 sClear dialogue and sharp surround effects
      Living room0.4–0.6 sRelaxed conversation and music
      Classroom or office0.4–0.7 sSpeech that is easy to follow
      Restaurant0.6–1.0 sSome life without shouting
      Concert hall1.8–2.2 sA warm, full orchestra
      Church1.5 s and upOrgan and choir; big stone churches reach 3 to 6 s

      In the bass, 1.2 to 1.5 times the mid value is normal and sounds warm. Much more than that sounds boomy. The treble bands are usually a little shorter than the mids, because air and soft furnishings absorb high sound. To see where each band starts and ends, look up the octave bands.

      The Sabine formula tab

      Choose Sabine estimate to predict RT60 before you measure or buy anything. Sabine’s formula is RT60 = 0.161 × V ÷ A, with the volume V in cubic metres and A the total absorption: each surface’s area times how much sound it soaks up. A 5 × 4 × 2.5 m room is 50 m³; with plaster walls, a wood floor and one sofa it comes out near 1.6 s, a bare and echoey room, and 10 m² of panels bring it to about 0.55 s. The tab also gives the Eyring result, which is closer for rooms with a lot of absorption, and the area of acoustic panels you would need to reach your room type’s target. The estimate assumes sound spreads evenly, so a real measurement always wins. For the next step after the reverb is right, read the room EQ guide, or see all the room acoustics tools.

      We may earn a commission if you buy through these links. It does not change the price.

      FAQ

      What is RT60?

      The time sound takes to fade by 60 dB after it stops: how long a room “rings”.

      What is a good RT60?

      0.2–0.4 s for a small studio, 0.4–0.6 s for a living room, 0.4–0.7 s for classrooms.

      Clap or balloon?

      A balloon pop has more bass energy and gives better low-band results; a clap is fine for mids and highs.

      Why is my result marked unreliable?

      The room was too noisy for a 35 dB decay. Try again when it is quieter or louder at the source.

      Written and tested by the SpectrumAnalyzer.app team · Last checked

      How we tested: Checked with the site's own room impulse response test file (RT60 0.6 s): T30 reads 0.60 to 0.63 s in every octave band from 125 Hz to 8 kHz and 0.60 s broadband, with an EDT of 0.62 s.