THD and distortion analyzer

Play a pure test tone through your gear, record it back and see THD, THD+N, SINAD and every harmonic.

Press Start to play the test tone

Connect a loopback cable from the output to the input for the cleanest result, or use the speaker and mic. Start with the volume low.

Or drop a recording of a test tone here.

THD—
THD+N—
SINAD—
Tone—

Test tone

Switch it off to measure a tone from another device, such as a signal generator or a test CD.

Harmonics
HarmonicHzdBFSdBc%

dBc = dB below the tone. “Below noise” harmonics are not counted as distortion; the THD then shows the most it can be.

System baseline

Averaging and source

Each spectrum is 32,768 points (0.7 s at 48 kHz). Sound is analysed on this device and never uploaded.

Export and share
Recent results
    Sound never leaves your device. Nothing is uploaded. Space start/stopF holdB baseline

    How to use the THD analyzer

    1. Choose the test tone: 1 kHz for amps and interfaces, 100 Hz for the bass of a speaker, or Custom.
    2. Connect the gear. For an audio interface or an amp’s line output, run a loopback cable from the output back to the input. For a speaker, put the mic 30 cm in front of it.
    3. Set the level low, press Start and allow the input. The tone plays and the results appear within a second, getting steadier as 8 spectra are averaged.
    4. Press Hold to keep a result, or Stop. The result is saved under Recent results.

    A loopback cable measures the electronics alone and gives the lowest numbers. A mic and speaker measure the whole chain, which is what you need for a speaker but adds the mic’s own distortion. You can also open a recording of a test tone made somewhere else, for example a 1 kHz tone recorded from an amp into a field recorder.

    How to read THD

    −60 −66 −80 noise THD = √(sum of harmonic powers) ÷ the tone = 0.112 % (−59 dB) Even: amber · Odd: coral 0−20−40−60−80H2H3H4H5Harmonic · dB below the 1 kHz tone
    The demo amplifier: three harmonics add up to 0.112 % THD.

    A perfect device would send back only the tone. Real ones add harmonics: copies of the tone at 2, 3, 4 and more times its frequency, so a 1 kHz tone grows extra tones at 2 kHz, 3 kHz and so on. THD, total harmonic distortion, adds up the power of harmonics H2 to H10 and compares it with the tone.

    % and dB

    The same number has two forms. 1 % is −40 dB, 0.1 % is −60 dB and 0.01 % is −80 dB: every factor of ten in % is 20 dB. THD+N also counts the noise and hum between 20 Hz and 20 kHz, so it is always a little higher, and SINAD is the same thing turned round: the tone plus everything, divided by everything but the tone. A SINAD of 80 dB equals 0.01 % THD+N. When all harmonics are hidden under the noise, the THD readout says “below the noise” and gives the most it could be.

    Which harmonics matter

    Low, even harmonics (H2, H4) sound warm and are hard to hear even at 1 %. Odd and high harmonics (H3, H5, H7 and up) sound harsh, and a little goes a long way: a row of odd harmonics that fall slowly is the mark of clipping. The bar chart colours even and odd harmonics differently, so you can tell a gently driven tube stage from an amp that is hitting its limit.

    Use cases

    Test an audio interface

    Connect a short cable from output 1 to input 1, set the input gain so the tone reads about −6 dBFS and measure at 1 kHz. A good modern interface reads under 0.005 % THD and above 90 dB SINAD; a cheap one may read 0.05 % and 75 dB. A setup like the Focusrite Scarlett Solo with a loopback cable is a common, simple test bench.

    We may earn a commission if you buy through these links. It does not change the price.

    Compare amps

    Feed each amp the same 1 kHz tone at the same output level, record the speaker output through a resistor divider or the amp’s line out, and compare. An amp that reads 0.02 % at normal levels but jumps to 3 % when you turn it up 3 dB has reached its clipping point.

    Find a speaker’s limit

    Play 100 Hz, put the mic 30 cm from the woofer and raise the volume in small steps. THD often climbs from 1 % to 10 % in the last few dB before the cone hits its limit. Stop when H3 rises fast, and keep the volume below that point. Save each step under Recent results to compare.

    Baseline: measure your system first

    Every chain adds its own distortion. A phone speaker and mic can read 1 % on their own, which would hide a 0.1 % amplifier completely. So measure the setup without the device first: the loopback cable alone, or the mic and a speaker you trust. Press Save as baseline. From then on the table and the bar chart show the baseline next to each result. If the device reads close to the baseline, it is at least as clean as your setup can show; if it reads three or more times higher, most of the distortion is the device’s own.

    A few habits make the numbers trustworthy. Aim for a returning tone of about −6 to −3 dBFS: much quieter and the noise hides the small harmonics, and at 0 dBFS the input clips, which the clipping badge shows. Use 16 averages when you compare two devices, so the result settles to the second decimal. Keep the cable short, and use the line output rather than a headphone output if the device has both, because headphone amps add their own distortion. With a mic, close the windows and switch off fans: room noise counts in THD+N, although it does not change THD. Phone mics with automatic gain can add distortion of their own, so measure the baseline with the same phone you test with.

    What THD numbers mean in practice

    Under 0.01 % is far below what anyone can hear and typical of good interfaces and DACs. Up to 0.1 % is normal for amplifiers at full power. Speakers are a different world: 1 % in the bass is common, and 3 to 10 % happens near their limits. Below about 1 % most listeners cannot hear distortion in music, but harsh odd harmonics are noticed sooner than warm even ones. For the noise side, see SNR and ENOB; for the tone balance of a speaker, run the frequency response test. More tests are in the speaker and audio test tools.

    FAQ

    What is a good THD?

    Under 0.1 % for amplifiers and interfaces; speakers are often 1 % or more in the bass.

    THD or THD+N?

    THD counts only harmonics; THD+N also counts noise, so it is always a bit higher.

    Why is my result high?

    The phone mic and speaker add distortion. Use a loopback cable and measure the baseline first.

    Which test tone should I use?

    1 kHz is the standard. Use 100 Hz to check bass distortion of speakers.

    Written and tested by the SpectrumAnalyzer.app team · Last checked

    How we tested: Checked with the site's own test files: the 60 Hz hum file with known harmonics reads H2 −6.0 dB and H3 −4.0 dB below the tone and THD 87.4 %, and a made-up amplifier with H2 −60, H3 −66 and H5 −80 dB reads 0.112 % THD.